JUMO TecLine C12 chlorine sensor
Measurement applications
- Drinking water
- Swimming pool water
- Service water
- Process water
- Cooling water
- Seawater (Types 202630/43 and /53).
Short description
The JUMO TecLine C12 is a membrane-covered amperometric sensor and is used to measure the concentration of free chlorine. The following anorganic chlorination agents can be measured: chlorine gas (Cl2), electrolytically generated chlorine, sodium hypochlorite (NaOCl, chlorine bleaching solution), calcium hypochlorite (Ca(OCl)2), or chlorinated lime (Ca(OCl)Cl).
The sensors are not suitable for detecting the absence of free chlorine.
The sensors’ integrated electronics provide a temperature-compensated current signal 4 to 20 mA for the variant with an analog output signal, and a Modbus RTU signal for the variant with a digital interface. A downstream device (Indicator, controller, recorder, PLC, etc) is used for calibration.
The sensors can be connected directly to various indicating devices/transmitters/controllers (See “Suitable indicating devices/transmitters/controllers “, page 10 of the data sheet document). They provide the voltage required for supplying the sensors and allow for easy calibration of the measuring system.
| Operating temperature | 0 to 45 °C |
|---|---|
| Environmental influences | 0 to 55 °C |
| Output signal | 4 to 20 mA, Modbus RTU |
| Electrical connection | 2-pin terminal connection (2 x 1 mm2), 5-pins flange connector M12 |
| Fitting length | 205 mm, 220 mm |
| Pressure resistance | P atmospheric max 2 bar, P atmospheric max 4 bar, P relatively max 1 bar, P relatively max 3 bar |
| Deviation | < 1% at 0,4 mg/l, < 1% at 1,6 mg/l, < 1% at 4 mg/l, < 3% at 16 mg/l |
| Measuring range | 0 to 200 mg/l (ppm), Or specific customer wishes |
| Material shell | Stainless steel 1.4571 |
| Response time | ±30 seconds to ±2 minutes (t90) |
| PH measuring range | PH 4 to PH 9 |
| Material membrane | PVC-U, PTFE |
| Diameter | 25 mm |
| Acclimate | 2 hours |
| Voltage supply | DC 12 to 30 V (Galvanic isolation required), DC 22,5 to 26 V (Galvanic isolation required from the sensor) |
| Membrane | Microporous hydrophilic membrane |
| Brand | JUMO |
| Order code | To view the possible options, you can find the options with the relevant codes in the Data sheet documents. Or contact us if you have specific wishes that are not in the documents |